Quick answer

Vibration and pressure do different jobs, and only one of them separates machine classes. Vibration frequency is published as 3,800 to 4,500 times a minute on every model in the range, so it cannot rank them. Vibration force runs from 58 kN on the QT5-15 to 280 kN on the QST1800, and rated pressure moves from 25 MPa on the two entry models to 31.5 MPa from the QST8-15 upward.

Get a price on WhatsApp Or send a written enquiry

A block machine datasheet lists a vibration frequency, a vibration force and a rated pressure, and buyers usually compare whichever number looks largest. The three answer different questions. One describes the rhythm of the table, one describes the energy behind it, and one describes how hard the pressing head can push the finished mix.

This page separates them, converts the force figure into a number that can be compared across pallet sizes, and lists what the datasheet leaves out. All values are the published specifications of the models on this site.

What does vibration do that pressure cannot?

The mix that goes into a block mould is semi-dry. It does not pour; it has to be shaken until it behaves like a liquid long enough to fill the cavity and flow around the core bars that form the hollows. That is the job of the vibrating table. Without it the mould would receive a loose heap with voids under the cores, and the pressing head would compact the heap as it stands, voids included.

Pressure then does the second job. Once the cavity is full and the mix is still moving, the pressing head squeezes it to the block height and forces the particles into contact. Vibration that fills a cavity without pressure gives a block too soft to strip and carry. Pressure without vibration gives a block with density that varies from the face to the core, and the cores are where the weakness shows first.

Is vibration frequency a way to compare two machines?

Not in this range. Every model publishes the same band, 3,800 to 4,500 times a minute, from the 12 t QST6-15 to the 34 t QST1800. A figure that does not move across a whole family cannot be the figure that ranks it. The band exists because it suits the semi-dry mixes these machines run, and the working frequency inside the band is set on site, not fixed by the catalogue.

What does move is the force behind the frequency and the mass that carries it. Vibration force steps from 58 kN on the QT5-15 to 68 kN on the QST6-15, 95 kN on the QST8-15, 105 kN on the QST1000, 150 kN on the QST1200, 220 kN on the QST1500 and 280 kN on the QST1800. Machine weight moves with it, from 6,900 kg on the smallest host to 34 t on the largest.

Force per square metre of pallet: the comparison the brochure skips

A bigger board spreads the same vibration over more square metres, so raw kilonewtons cannot be compared between models without the board area next to them. Divide force by pallet area and the range sorts itself out.

ModelPallet areaVibration forceForce per square metreRated pressure
QT5-150.72 m258 kN81 kN/m225 MPa
QST6-150.67 m268 kN102 kN/m225 MPa
QST8-150.84 m295 kN113 kN/m231.5 MPa
QST10000.97 m2105 kN108 kN/m231.5 MPa
QST12001.19 m2150 kN126 kN/m231.5 MPa
QST15001.55 m2220 kN142 kN/m231.5 MPa
QST18001.96 m2280 kN143 kN/m231.5 MPa

Where do 25 MPa and 31.5 MPa actually differ?

The force column rises steadily, from 81 kN per square metre on the QT5-15 to 143 on the QST1800, and it is not a perfectly straight line. The QST8-15 delivers 113 kN per square metre on a 0.84 square metre board while the QST1000 delivers 108 on 0.97 square metres. The QST1000 still produces more per cycle, because its board carries more cavities. Reading board area and force together is what prevents that pair from looking like a contradiction.

Rated pressure follows a simpler rule. The QT5-15 and QST6-15 are rated 25 MPa, and every model from the QST8-15 upward is rated 31.5 MPa. Those two entry presses are also the two that run 20 mm boards, so the pressure rating tracks the class of the frame rather than standing alone as a quality claim. A 31.5 MPa rating is only useful if the frame, the mould and the board can carry it, which is why the rating belongs in the same sentence as the machine weight.

Does a shorter cycle mean a denser block?

No. Cycle time covers feeding, vibrating, pressing, stripping and returning the board, and the models in this range sit inside a narrow band, from 15 to 20 seconds on the QT5-15 and 15 to 25 seconds on the QST1200 and QST1800. The QST6-15 and the QST8-15 share a cycle of 15 to 23 seconds while running 68 and 95 kN at 25 and 31.5 MPa, which on its own shows the cycle says nothing about the forming energy.

A cycle can always be shortened by cutting the vibration time, and the block still leaves the press. It leaves lighter, with the arris weaker and the face less closed, and the fault appears days later on the truck or in the wall. That is why the cycle should be read as a production figure and the force as a forming figure, and the two should never be traded against each other on the same line of a comparison sheet.

What does the datasheet leave out, and what should you send?

Four things that decide how the forming energy reaches the mix are not in the table, and they are worth asking about in writing before a quotation is compared on kilonewtons alone.

  • Vibration amplitude, not just force. Two tables can share a force figure and move the mix by different distances.
  • Whether the table or the mould vibrates, since it changes how the energy reaches a tall block.
  • The frequency actually set for your mix at commissioning, as opposed to the published band.
  • How the force figure was measured: on the table, on the mould, or at the motor.

With those answers plus five parameters, a model can be matched to your product instead of to a brochure. The five are the block and paver sizes with their heights, the pieces per cycle you want, the pallet size already in the plant if any, the strength class your market buys, and the mix you intend to run, with the aggregate and the cement grade you can actually get.

Send those and we will return the model class, the vibration force and rated pressure of the proposed machine, the mould set that matches the pallet, and the power and air demand the plant has to supply, so the comparison is made on forming data rather than on the biggest number in the catalogue.

Frequently asked questions

Is higher vibration force always better?

Only up to what the mould, the board and the product can take. A force matched to the board area fills cavities evenly; a force beyond what the mix and the cores can absorb starts to segregate the aggregate and to hammer the mould. The useful comparison is force per square metre of pallet next to the product height, not the headline kilonewtons.

Can I raise the rated pressure on an existing machine?

Not as a setting change. The rating is carried by the frame, the cylinders, the mould and the board together, and raising it on one of them alone moves the wear somewhere else. What can be adjusted on site is the cycle and the vibration time, both of which are commissioning settings rather than specifications.

Why do QST6-15 and QST8-15 share a cycle time?

Because the cycle is set by the sequence of movements, not by the size of the press. Both machines run the same sequence at 15 to 23 seconds, yet one carries 68 kN of vibration force at 25 MPa on a 980 by 680 mm board and the other 95 kN at 31.5 MPa on a 980 by 860 mm board. Identical cycle times with different forming energy is the clearest proof that the two figures should be read separately.

Price guides
Machines that fit this

Want an engineering opinion on your project?

Tell us what you want to produce and which raw materials you have, and we will recommend the right machine.

Talk to an engineer

Related reading

Request a quotation

A machine list, a layout drawing and a price, usually within one working day.

We reply within 12 hours. Your information is never shared.

WhatsApp Us