Electricity Consumption of a Block Making Machine

3 November 2026 · 7 min read

Quick answer

Electricity consumption of a block making machine is set by pieces per hour, not by the nameplate total. A QST6-15 lists 34.4 kW plus 3.0 kW for the stacker, and at a 20 second cycle it makes 1,080 hollow blocks an hour, so 37.4 kWh over 1,080 blocks is about 35 kWh per 1,000 at full load. A real meter reads lower than that, because the pump unloads between cycles.

Get a price on WhatsApp Or send a written enquiry

Electricity consumption of a block making machine is not the sum printed on its motor nameplates. That sum is installed capacity, the figure that sizes the cable, the transformer and the generator. What the utility charges for is average draw, and on every block line it sits below the nameplate total. The gap between the two numbers is where most buying mistakes begin.

Two questions follow from that split. Can the supply carry the machine while it starts? How many kilowatt hours does a thousand blocks cost? The first is answered by adding motor ratings and checking the largest start. The second needs a meter at the intake and a count of the pallets that came off the racks.

Which number do buyers confuse, capacity or draw?

Installed capacity is the additive figure. It is every motor nameplate on the press, plus the stacker, plus whatever else hangs on the same panel. It exists for the electrical design: conductor cross section, protection settings, transformer rating, and the starting margin the supply must absorb. Nothing on site is sized from an average, because an average never starts a motor.

Average draw is the accumulating figure, and it is lower because the work is intermittent. The pump builds pressure, holds it while the mould vibrates, then unloads. The vibrators fire for seconds and rest. The stacker lifts one pallet and waits. A 34.4 kW press would only eat 34.4 kWh an hour if every motor pulled full current for sixty minutes.

What does the QST6-15 use per 1,000 hollow blocks?

Start from the published table and the arithmetic runs itself. The press carries 34.4 kW installed, the stacking machine adds 3.0 kW, so the line totals 37.4 kW at full load. The forming cycle is 15 to 23 seconds and the mould carries six hollow blocks of 390 x 190 x 190 mm. Published shift output is 8,640 to 11,520 blocks in eight hours.

Take the 20 second end of that range. One hour holds 180 cycles of 20 seconds, and six blocks a cycle gives 1,080 hollow blocks in the hour. Eight hours of the same rhythm is the 8,640 at the bottom of the published range, which confirms the inputs before any energy figure is used.

Now hold 37.4 kW for that hour and the result is 37.4 kWh. Spread over 1,080 blocks that is about 35 kWh per 1,000 hollow blocks at full installed load. The 23 second cycle pushes the same figure up, because it delivers fewer blocks in the hour. Treat 35 as a ceiling, not a forecast: between cycles the pump unloads, so a working machine meters under it.

How much does the QS600 use per 1,000 pavers?

The static side answers the same question with different mechanics. A QS600 carries 46.9 kW in total and presses 16 pavers of 200 x 100 x 60 mm in each mould, on a 900 x 700 x 20 mm pallet. The cycle runs 20 to 25 seconds at a maximum pressure of 31.5 MPa.

At 20 seconds an hour holds 180 cycles and 2,880 pavers. At 25 seconds it holds 144 cycles and 2,304 pavers. Put 46.9 kWh against those two counts and the result is about 16 to 20 kWh per 1,000 pavers at installed load. The low end comes with the fast cycle, the high end with the slow one.

The two examples are not a ranking. A static press runs one hydraulic pump and holds pressure longer in each cycle, with no vibration motors in the panel. A vibrating machine splits its draw between pump and vibrators in short bursts. Compare machines on kWh per 1,000 pieces, never on kilowatts alone.

Where do the kilowatts actually go?

Five loads share the cable, and each behaves differently through a cycle. The hydraulic power unit is the largest item on both machine types, because it lifts the mould, closes the press and pushes the pallet out. Vibration motors come second and draw hard for seconds at a time.

The stacker is the smallest item and the easiest to forget, at 3.0 kW on a QST6-15. Next comes the compressor on the feed box, then the mixer. Added together they make a plant figure rather than a machine figure.

Size the mixer on its own. It works at a different rhythm, at a higher rating for shorter bursts, and it keeps running whether or not a pallet is forming. The mobile mixing stations in the same catalogue list 65 to 100 kW of total power against 34.4 kW on the press. One merged figure hides both halves.

What pushes the number up on a real site?

The arithmetic assumes a clean supply, dry sand and a machine set up properly. Five conditions move the meter up, and four are site faults. Each leaves a signature on the meter.

  • Start current. A motor pulls several times its running current while it accelerates, so every stop and restart lands on the meter as energy that produced no blocks. Group the stops and let the line idle between orders instead of cycling the panel.
  • Voltage drop. A long thin run from the transformer leaves the motors short of voltage at the terminals. They pull more current for the same mechanical work, and the excess leaves as heat in the winding and in the cable.
  • A generator larger than the plant needs. A big set running far below its rating delivers each kilowatt hour at a worse fuel rate, and its own losses are counted before the machine sees anything. The blocks are the same, the energy behind them is dearer.
  • Damp mould sand. Wet sand packs poorly, so the feed box needs longer and the vibrators run longer to fill the same mould. The cycle stretches, output per hour falls, and every block in that batch carries more kilowatt hours.
  • A relief valve set too low. The machine is rated at 25 MPa for a reason, and a valve that cracks early dumps oil back to the tank while the pump keeps pulling current. The gauge reads low, the block comes out soft, and the energy went into heating hydraulic oil.

How do you measure consumption in a single shift?

You need a meter, a notebook, a pallet count and one ordinary shift. Read the incoming meter at the start, write down the reading and the clock time, then read it again at the end. The difference is that shift's energy, lights and compressor included.

Count the product, not the cycles. Walk the racks and count pallets, multiply by pieces per pallet, and write the total down before the pallets are cubed and the count is lost. A hand count is accurate enough for this purpose and takes minutes.

Divide kilowatt hours by thousands of pieces. A vibration machine that lands near 35 kWh per 1,000 hollow blocks is close to full installed load, which is the ceiling of the worked example. A static press near 16 to 20 per 1,000 pavers sits in the same place. Well above either figure means a site fault.

Repeat the reading on a normal product and a normal shift. A short trial with dry sand flatters any machine, and the first shift after a long stoppage punishes it.

Frequently asked questions

How many kWh does a block making machine use per 1,000 blocks?

About 35 kWh per 1,000 hollow blocks on a QST6-15 at full installed load, and less on a tuned line. Six blocks per mould at a 20 second cycle give 1,080 blocks an hour, and 37.4 kW for that hour is 37.4 kWh. A QS600 static press runs about 16 to 20 kWh per 1,000 pavers.

Why does the meter read below the installed capacity?

Because no motor runs at its nameplate for a whole hour. The hydraulic pump unloads between cycles, the vibrators fire in bursts, the feeder pauses and the stacker waits. Installed capacity sizes cables, protection and the transformer, and it assumes a simultaneous full draw that a working cycle never produces.

Does a static press consume less power than a vibrating machine?

Per thousand pieces it often does, though its nameplate is bigger. The QS600 carries 46.9 kW against 34.4 kW on the QST6-15, and it makes 2,304 to 2,880 pavers an hour at 16 to 20 kWh per 1,000. The difference comes from one hydraulic pump and no vibration motors, not from a lower rating.

What is the difference between installed capacity and average draw?

Installed capacity adds every motor nameplate and sizes the electrical design. Average draw is what the meter accumulates over a shift, and it is always lower. On a QST6-15 the panel totals 37.4 kW with the stacker, and that spread over 1,080 blocks an hour gives roughly 35 kWh per 1,000.

When should the mixer be metered separately?

Always, if it draws from the same supply as the press. The mixer works at a higher rating for shorter bursts and often keeps running when no pallet is forming, so folding it into the press figure hides both. A mixing station in the same catalogue lists 65 to 100 kW total against 34.4 kW on the press.

Price guides
Machines that fit this
Machines used in this process

Want an engineering opinion on your project?

Tell us what you want to produce and which raw materials you have, and we will recommend the right machine.

Talk to an engineer

Related reading

Request a quotation

A machine list, a layout drawing and a price, usually within one working day.

We reply within 12 hours. Your information is never shared.

WhatsApp Us